| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| An issue in WoFit v.7.2.3 allows a remote attacker to obtain sensitive information via the firmware update process |
| WODESYS WD-R608U router (also known as WDR122B V2.0 and WDR28) is vulnerable to Broken Access Control in initial configuration wizard.cgi endpoint. Malicious attacker can change admin panel password without authorization. The vulnerability can also be exploited after the initial configuration has been set.
The vendor was notified early about this vulnerability, but didn't respond with the details of vulnerability or vulnerable version range. Only version WDR28081123OV1.01 was tested and confirmed as vulnerable, other versions were not tested and might also be vulnerable. |
| The Crypto plugin for WordPress is vulnerable to Information exposure in all versions up to, and including, 2.22. This is due to the plugin registering an unauthenticated AJAX action (wp_ajax_nopriv_crypto_connect_ajax_process) that allows calling the register and savenft methods with only a publicly-available nonce check and no wallet signature verification. This makes it possible for unauthenticated attackers to set a site-wide global authentication state via a single transient, bypassing all access controls for ALL visitors to the site. The impact is complete bypass of [crypto-block] shortcode restrictions and page-level access controls, affecting all site visitors for one hour, plus the ability to inject arbitrary data into the plugin's custom_users table. |
| An authenticated command injection vulnerability exists in OP5 Monitor through version 7.1.9 via the 'cmd_str' parameter in the command_test.php endpoint. A user with access to the web interface can exploit the 'Test this command' feature to execute arbitrary shell commands as the unprivileged web application user. The vulnerability resides in the configuration section of the application and requires valid login credentials with access to the command testing functionality. This issue is fixed in version 7.2.0. |
| Missing authentication for critical function issue exists in I-O DATA network attached hard disk 'HDL-T Series' firmware Ver.1.21 and earlier. If exploited, a remote unauthenticated attacker may change the product settings. |
| A low privileged remote attacker may modify the docker settings setup of the device, leading to a limited DoS. |
| General Industrial Controls Lynx+ Gateway
is missing critical authentication in the embedded web server which could allow an attacker to remotely reset the device. |
| Astak CM-818T3 2.4GHz wireless security surveillance cameras contain an unauthenticated configuration disclosure vulnerability in the /web/cgi-bin/hi3510/backup.cgi endpoint. The endpoint permits remote download of a compressed configuration backup without requiring authentication or authorization. The exposed backup may include administrative credentials and other sensitive device settings, enabling an unauthenticated remote attacker to obtain information that could facilitate further compromise of the camera or connected network. |
| Anheng Mingyu Operation and Maintenance Audit and Risk Control System up to 2023-08-10 contains a server-side request forgery (SSRF) vulnerability in the xmlrpc.sock handler. The product accepts specially crafted XML-RPC requests that can be used to instruct the server to connect to internal unix socket RPC endpoints and perform privileged XML-RPC methods. An attacker able to send such requests can invoke administrative RPC methods via the unix socket interface to create arbitrary user accounts on the system, resulting in account creation and potential takeover of the bastion host. VulnCheck has observed this vulnerability being exploited in the wild as of 2025-10-30 at 00:30:17.837319 UTC. |
| CVE-2025-1701 is a high-severity vulnerability in the MIM Admin service. An attacker could exploit this vulnerability by sending a specially crafted request over the RMI interface to execute arbitrary code with the privileges of the MIM Admin service. The RMI interface is only accessible locally (listening on 127.0.0.1), limiting the attack vector to the local machine. This means that in a properly configured hospital environment, an attacker must have already compromised the network and additionally compromised the system where the MIM Admin service is running. From there, attackers with sufficient knowledge of MIM's implementation, library usage, and functionality with access to extend the MIM RMI library could force the MIM Admin service to run commands on the local machine with its privileges.
Users of MIM Software products exposed via RDP or multi-user application virtualization system should take note that the system being exposed is the environment hosting the virtualized MIM client.
This issue affects MIM Admin Service: before 7.2.13, 7.3.8, 7.4.3 |
| Missing authentication for critical function vulnerability exists in Wi-Fi AP UNIT 'AC-WPS-11ac series'. If exploited, a remote unauthenticated attacker may obtain the product configuration information including authentication information. |
| Missing Authentication, Files or Directories Accessible to External Parties, Use of Hard-coded Credentials vulnerability in Talya Informatics Elektraweb allows Authentication Bypass.This issue affects Elektraweb: before v17.0.68. |
| The "serverConfig" endpoint, which returns the module configuration including credentials, is accessible without authentication. |
| An issue in Quectel BC95-CNV V100R001C00SPC051 allows attackers to bypass authentication via a crafted NAS message. |
| An issue in Quectel BG96 BG96MAR02A08M1G allows attackers to bypass authentication via a crafted NAS message. NOTE: this is disputed by the supplier. |
| An issue in Plug n Play Camera com.ezset.delaney 1.2.0 allows a remote attacker to obtain sensitive information via the firmware update process. |
| The wifi module exposes the interface and has improper permission control, leaking sensitive information about the device. |
| Peppermint Ticket Management 0.4.6 is vulnerable to Incorrect Access Control. A regular registered user is able to elevate his privileges to admin and gain complete access to the system as the authorization mechanism is not validated on the server side and only on the client side. This can result, for example, in creating a new admin user in the system which enables persistent access for the attacker as an administrator. |
| Certain Anpviz products allow unauthenticated users to modify or disable camera related settings such as microphone volume, speaker volume, LED lighting, NTP, motion detection, etc. This affects IPC-D250, IPC-D260, IPC-B850, IPC-D850, IPC-D350, IPC-D3150, IPC-D4250, IPC-D380, IPC-D880, IPC-D280, IPC-D3180, MC800N, YM500L, YM800N_N2, YMF50B, YM800SV2, YM500L8, and YM200E10 firmware v3.2.2.2 and lower and possibly more vendors/models of IP camera. |
| Dover Fueling Solutions ProGauge MagLink LX Consoles expose an undocumented and unauthenticated target communication framework (TCF) interface on a specific port. Files can be created, deleted, or modified, potentially leading to remote code execution. |