CVE-2020-16200 1 Philips 1 Clinical Collaboration Platform 2025-06-04 6.5 Medium
Philips Clinical Collaboration Platform, Versions 12.2.1 and prior, does not properly control the allocation and maintenance of a limited resource, thereby enabling an attacker to influence the amount of resources consumed, eventually leading to the exhaustion of available resources.
CVE-2020-16198 1 Philips 1 Clinical Collaboration Platform 2025-06-04 5 Medium
When an attacker claims to have a given identity, Philips Clinical Collaboration Platform, Versions 12.2.1 and prior, does not prove or insufficiently proves the claim is correct.
CVE-2020-14525 1 Philips 1 Clinical Collaboration Platform 2025-06-04 3.5 Low
Philips Clinical Collaboration Platform, Versions 12.2.1 and prior, does not neutralize or incorrectly neutralizes user-controllable input before it is placed in output used as a webpage that is served to other users.
CVE-2020-14518 1 Philips 1 Dreammapper 2025-06-04 5.3 Medium
Philips DreamMapper, Version 2.24 and prior. Information written to log files can give guidance to a potential attacker.
CVE-2020-14477 1 Philips 16 Affiniti 50, Affiniti 50 Firmware, Affiniti 70 and 13 more 2025-06-04 3.6 Low
In Philips Ultrasound ClearVue Versions 3.2 and prior, Ultrasound CX Versions 5.0.2 and prior, Ultrasound EPIQ/Affiniti Versions VM5.0 and prior, Ultrasound Sparq Version 3.0.2 and prior and Ultrasound Xperius all versions, an attacker may use an alternate path or channel that does not require authentication of the alternate service login to view or modify information.
CVE-2020-12023 1 Philips 1 Intellibridge Enterprise 2025-06-04 2 Low
Philips IntelliBridge Enterprise (IBE), Versions B.12 and prior, IntelliBridge Enterprise system integration with SureSigns (VS4), EarlyVue (VS30) and IntelliVue Guardian (IGS). Unencrypted user credentials received in the IntelliBridge Enterprise (IBE) are logged within the transaction logs, which are secured behind the login based administrative web portal. The unencrypted user credentials sent from the affected products listed above, for the purpose of handshake or authentication with the Enterprise Systems, are logged as the payload in IntelliBridge Enterprise (IBE) within the transaction logs. An attacker with administrative privileges could exploit this vulnerability to read plain text credentials from log files.
CVE-2020-27298 1 Philips 5 Coronary Tools, Dynamic Coronary Roadmap, Interventional Workspot and 2 more 2025-06-04 6.5 Medium
Philips Interventional Workspot (Release 1.3.2, 1.4.0, 1.4.1, 1.4.3, 1.4.5), Coronary Tools/Dynamic Coronary Roadmap/Stentboost Live (Release 1.0), ViewForum (Release 6.3V1L10). The software constructs all or part of an OS command using externally influenced input from an upstream component but does not neutralize or incorrectly neutralizes special elements that could modify the intended OS command when sent to a downstream component.
CVE-2020-14506 1 Philips 1 Clinical Collaboration Platform 2025-06-04 3.4 Low
Philips Clinical Collaboration Platform, Versions 12.2.1 and prior. The product receives input or data, but it does not validate or incorrectly validates that the input has the properties required to process the data safely and correctly.
CVE-2017-14111 1 Philips 2 Intellispace Cardiovascular, Xcelera 2025-04-20 N/A
The workstation logging function in Philips IntelliSpace Cardiovascular (ISCV) 2.3.0 and earlier and Xcelera R4.1L1 and earlier records domain authentication credentials, which if accessed allows an attacker to use credentials to access the application, or other user entitlements.
CVE-2015-2883 1 Philips 1 In.sight B120\\37 2025-04-20 N/A
Philips In.Sight B120/37 has XSS, related to the Weaved cloud web service, as demonstrated by the name parameter to deviceSettings.php or shareDevice.php.
CVE-2015-2884 1 Philips 1 In.sight B120\\37 2025-04-20 N/A
Philips In.Sight B120/37 allows remote attackers to obtain sensitive information via a direct request, related to yoics.net URLs, stream.m3u8 URIs, and cam_service_enable.cgi.
CVE-2015-2882 1 Philips 1 In.sight B120\\37 2025-04-20 N/A
Philips In.Sight B120/37 has a password of b120root for the backdoor root account, a password of /ADMIN/ for the backdoor admin account, a password of merlin for the backdoor mg3500 account, a password of M100-4674448 for the backdoor user account, and a password of M100-4674448 for the backdoor admin account.
CVE-2017-14797 1 Philips 2 Hue Bridge Bsb002, Hue Bridge Bsb002 Firmware 2025-04-20 N/A
Lack of Transport Encryption in the public API in Philips Hue Bridge BSB002 SW 1707040932 allows remote attackers to read API keys (and consequently bypass the pushlink protection mechanism, and obtain complete control of the connected accessories) by leveraging the ability to sniff HTTP traffic on the local intranet network.
CVE-2021-27497 1 Philips 4 Myvue, Speech, Vue Motion and 1 more 2025-04-17 6.5 Medium
Philips Vue PACS versions 12.2.x.x and prior does not use or incorrectly uses a protection mechanism that provides sufficient defense against directed attacks against the product.
CVE-2021-27493 1 Philips 4 Myvue, Speech, Vue Motion and 1 more 2025-04-17 6.1 Medium
Philips Vue PACS versions 12.2.x.x and prior does not ensure or incorrectly ensures structured messages or data are well formed and that certain security properties are met before being read from an upstream component or sent to a downstream component.
CVE-2021-27501 1 Philips 4 Myvue, Speech, Vue Motion and 1 more 2025-04-16 7.5 High
Philips Vue PACS versions 12.2.x.x and prior does not follow certain coding rules for development, which can lead to resultant weaknesses or increase the severity of the associated vulnerabilities.
CVE-2021-33018 1 Philips 4 Myvue, Speech, Vue Motion and 1 more 2025-04-16 7.5 High
The use of a broken or risky cryptographic algorithm in Philips Vue PACS versions 12.2.x.x and prior is an unnecessary risk that may result in the exposure of sensitive information.
CVE-2021-23173 1 Philips 1 Engage 2025-04-16 2.6 Low
The affected product is vulnerable to an improper access control, which may allow an authenticated user to gain unauthorized access to sensitive data.
CVE-2021-33020 1 Philips 4 Myvue, Speech, Vue Motion and 1 more 2025-04-16 8.2 High
Philips Vue PACS versions 12.2.x.x and prior uses a cryptographic key or password past its expiration date, which diminishes its safety significantly by increasing the timing window for cracking attacks against that key.
CVE-2021-33024 1 Philips 4 Myvue, Speech, Vue Motion and 1 more 2025-04-16 3.7 Low
Philips Vue PACS versions 12.2.x.x and prior transmits or stores authentication credentials, but it uses an insecure method susceptible to unauthorized interception and/or retrieval.