| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| LCDS LAquis SCADA through 4.3.1.1085 is vulnerable to a control bypass and path traversal. If an attacker can get a victim to load a malicious els project file and use the play feature, then the attacker can bypass a consent popup and write arbitrary files to OS locations where the user has permission, leading to code execution. |
| mySCADA myDESIGNER 8.20.0 and below allows Directory Traversal attacks when importing project files. If an attacker can trick a victim into importing a malicious mep file, then they gain the ability to write arbitrary files to OS locations where the user has permission. This would typically lead to code execution. |
| Hitachi Content Platform Anywhere (HCP-AW) 4.4.5 and later allows information disclosure. If authenticated user creates a link to a file or folder while the system was running version 4.3.x or earlier and then shares the link and then later deletes the file or folder without deleting the link and before the link expires. If the system has been upgraded to version 4.4.5 or 4.5.0 a malicious user with the link could browse and download all files of the authenticated user that created the link . |
| SAS/Intrnet 9.4 build 1520 and earlier allows Local File Inclusion. The samples library (included by default) in the appstart.sas file, allows end-users of the application to access the sample.webcsf1.sas program, which contains user-controlled macro variables that are passed to the DS2CSF macro. Users can escape the context of the configured user-controllable variable and append additional functions native to the macro but not included as variables within the library. This includes a function that retrieves files from the host OS. |
| ARCHIBUS Web Central 21.3.3.815 (a version from 2014) does not properly validate requests for access to data and functionality in these affected endpoints: /archibus/schema/ab-edit-users.axvw, /archibus/schema/ab-data-dictionary-table.axvw, /archibus/schema/ab-schema-add-field.axvw, /archibus/schema/ab-core/views/process-navigator/ab-my-user-profile.axvw. By not verifying the permissions for access to resources, it allows a potential attacker to view pages that are not allowed. Specifically, it was found that any authenticated user can reach the administrative console for user management by directly requesting access to the page via URL. This allows a malicious user to modify all users' profiles, to elevate any privileges to administrative ones, or to create or delete any type of user. It is also possible to modify the emails of other users, through a misconfiguration of the username parameter, on the user profile page. This is fixed in all recent versions, such as version 26. NOTE: This vulnerability only affects products that are no longer supported by the maintainer. Version 21.3 was officially de-supported by the end of 2020 |
| CommScope SURFboard SBG6950AC2 9.1.103AA23 devices allow Command Injection. |
| Leostream Connection Broker 9.0.40.17 allows administrator to upload and execute Perl code. |
| A vulnerability has been identified in Teamcenter Active Workspace V4.3 (All versions < V4.3.11), Teamcenter Active Workspace V5.0 (All versions < V5.0.10), Teamcenter Active Workspace V5.1 (All versions < V5.1.6), Teamcenter Active Workspace V5.2 (All versions < V5.2.3). The application contains an unsafe unzipping pattern that could lead to a zip path traversal attack. This could allow and attacker to execute a remote shell with admin rights. |
| A vulnerability has been identified in RUGGEDCOM ROX MX5000 (All versions < V2.14.1), RUGGEDCOM ROX RX1400 (All versions < V2.14.1), RUGGEDCOM ROX RX1500 (All versions < V2.14.1), RUGGEDCOM ROX RX1501 (All versions < V2.14.1), RUGGEDCOM ROX RX1510 (All versions < V2.14.1), RUGGEDCOM ROX RX1511 (All versions < V2.14.1), RUGGEDCOM ROX RX1512 (All versions < V2.14.1), RUGGEDCOM ROX RX1524 (All versions < V2.14.1), RUGGEDCOM ROX RX1536 (All versions < V2.14.1), RUGGEDCOM ROX RX5000 (All versions < V2.14.1). Affected devices write crashdumps without checking if enough space is available on the filesystem. Once the crashdump fills the entire root filesystem, affected devices fail to boot successfully. An attacker can leverage this vulnerability to cause a permanent Denial-of-Service. |
| A vulnerability has been identified in Desigo DXR2 (All versions < V01.21.142.5-22), Desigo PXC3 (All versions < V01.21.142.4-18), Desigo PXC4 (All versions < V02.20.142.10-10884), Desigo PXC5 (All versions < V02.20.142.10-10884). When the controller receives a specific BACnet protocol packet, an exception causes the BACnet communication function to go into a “out of work” state and could result in the controller going into a “factory reset” state. |
| A vulnerability has been identified in Siemens Software Center (All versions < V3.0). A DLL Hijacking vulnerability could allow a local attacker to execute code with elevated privileges by placing a malicious DLL in one of the directories on the DLL search path. |
| A vulnerability has been identified in Solid Edge SE2021 (All versions < SE2021MP8). The affected application contains a use-after-free vulnerability while parsing OBJ files. An attacker could leverage this vulnerability to execute code in the context of the current process (ZDI-CAN-13776). |
| A vulnerability has been identified in Solid Edge SE2021 (All versions < SE2021MP8). The affected application contains a use-after-free vulnerability while parsing OBJ files. An attacker could leverage this vulnerability to execute code in the context of the current process (ZDI-CAN-13773). |
| A vulnerability has been identified in Solid Edge SE2021 (All versions < SE2021MP8). The affected application contains a use-after-free vulnerability while parsing OBJ files. An attacker could leverage this vulnerability to execute code in the context of the current process (ZDI-CAN-13789). |
| A vulnerability has been identified in Solid Edge SE2021 (All versions < SE2021MP8). The affected application contains a use-after-free vulnerability while parsing OBJ files. An attacker could leverage this vulnerability to execute code in the context of the current process (ZDI-CAN-13778). |
| A vulnerability has been identified in NX 1953 Series (All versions < V1973.3700), NX 1980 Series (All versions < V1988), Solid Edge SE2021 (All versions < SE2021MP8). The affected application contains a use-after-free vulnerability while parsing OBJ files. An attacker could leverage this vulnerability to execute code in the context of the current process (ZDI-CAN-13771). |
| NLnet Labs Routinator prior to 0.10.0 produces invalid RTR payload if an RPKI CA uses too large values in the max-length parameter in a ROA. This will lead to RTR clients such as routers to reject the RPKI data set, effectively disabling Route Origin Validation. |
| Forcepoint NGFW Engine versions 6.5.11 and earlier, 6.8.6 and earlier, and 6.10.0 are vulnerable to TCP reflected amplification vulnerability, if HTTP User Response has been configured. |
| A vulnerability has been reported in the windows installer (MSI) built with InstallScript custom action. This vulnerability may allow privilege escalation when invoked ‘repair’ of the MSI which has an InstallScript custom action. |
| While fuzzing the 2.4.49 httpd, a new null pointer dereference was detected during HTTP/2 request processing, allowing an external source to DoS the server. This requires a specially crafted request. The vulnerability was recently introduced in version 2.4.49. No exploit is known to the project. |