Search Results (349374 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2024-10665 1 Wordpress 1 Wordpress 2026-04-15 5.4 Medium
The Yaad Sarig Payment Gateway For WC plugin for WordPress is vulnerable to unauthorized modification & access of data due to a missing capability check on the yaadpay_view_log_callback() and yaadpay_delete_log_callback() functions in all versions up to, and including, 2.2.4. This makes it possible for authenticated attackers, with Subscriber-level access and above, to view and delete logs.
CVE-2020-24102 1 Evenbalance 1 Punkbuster 2026-04-15 7.6 High
Directory Traversal vulnerability in Punkbuster pbsv.d64 2.351, allows remote attackers to execute arbitrary code.
CVE-2025-2351 2026-04-15 7.3 High
A vulnerability classified as critical was found in DayCloud StudentManage 1.0. This vulnerability affects unknown code of the file /admin/adminScoreUrl of the component Login Endpoint. The manipulation of the argument query leads to sql injection. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. Continious delivery with rolling releases is used by this product. Therefore, no version details of affected nor updated releases are available. The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2025-32008 1 Intel 1 Intel Amt And Intel Standard Manageability 2026-04-15 8.6 High
Out-of-bounds write in the firmware for the Intel(R) AMT and Intel(R) Standard Manageability within Ring 3: User Applications may allow a denial of service. Network adversary with an unauthenticated user combined with a low complexity attack may enable denial of service. This result may potentially occur via network access when attack requirements are not present without special internal knowledge and requires no user interaction. The potential vulnerability may impact the confidentiality (none), integrity (none) and availability (high) of the vulnerable system, resulting in subsequent system confidentiality (none), integrity (none) and availability (low) impacts.
CVE-2025-32002 2026-04-15 9.8 Critical
Improper neutralization of special elements used in an OS command ('OS Command Injection') issue exists in I-O DATA network attached hard disk 'HDL-T Series' firmware Ver.1.21 and earlier when 'Remote Link3 function' is enabled. If exploited, a remote unauthenticated attacker may execute an arbitrary OS command.
CVE-2025-31992 1 Hcltech 1 Maxai Assistant 2026-04-15 4.6 Medium
HCL Unica MaxAI Assistant is susceptible to a HTML injection vulnerability. An attacker could insert special characters that are processed client-side in the context of the user's session.
CVE-2025-31979 2026-04-15 5.4 Medium
A File Upload Validation Bypass vulnerability has been identified in the HCL BigFix SM, where the application fails to properly enforce file type restrictions during the upload process. An attacker may exploit this flaw to upload malicious or unauthorized files, such as scripts, executables, or web shells, by bypassing client-side or server-side validation mechanisms.
CVE-2025-31946 2026-04-15 6.2 Medium
Pixmeo OsiriX MD is vulnerable to a local use after free scenario, which could allow an attacker to locally import a crafted DICOM file and cause memory corruption or a system crash.
CVE-2025-2346 2026-04-15 5.6 Medium
A vulnerability has been found in IROAD Dash Cam X5 and Dash Cam X6 up to 20250308 and classified as problematic. This vulnerability affects unknown code of the component Domain Handler. The manipulation of the argument Domain Name leads to origin validation error. The attack can be initiated remotely. The complexity of an attack is rather high. The exploitation appears to be difficult.
CVE-2025-24391 1 Otrs 1 Otrs 2026-04-15 5.3 Medium
A vulnerability in the External Interface of OTRS allows conclusions to be drawn about the existence of user accounts through different HTTP response codes and messages. This enables an attacker to systematically identify valid email addresses. This issue affects: * OTRS 7.0.X * OTRS 8.0.X * OTRS 2023.X * OTRS 2024.X * OTRS 2025.X
CVE-2025-31940 1 Intel 1 Thread Director Visualizer Software 2026-04-15 6.7 Medium
Incorrect default permissions for some Intel(R) Thread Director Visualizer software before version 1.1.1 within Ring 3: User Applications may allow an escalation of privilege. Unprivileged software adversary with an authenticated user combined with a high complexity attack may enable escalation of privilege. This result may potentially occur via local access when attack requirements are present without special internal knowledge and requires active user interaction. The potential vulnerability may impact the confidentiality (high), integrity (high) and availability (high) of the vulnerable system, resulting in subsequent system confidentiality (none), integrity (none) and availability (none) impacts.
CVE-2025-31930 2026-04-15 8.8 High
A vulnerability has been identified in IEC 1Ph 7.4kW Child socket (8EM1310-2EH04-0GA0) (All versions < V2.135), IEC 1Ph 7.4kW Child socket/ shutter (8EM1310-2EN04-0GA0) (All versions < V2.135), IEC 1Ph 7.4kW Parent cable 7m (8EM1310-2EJ04-3GA1) (All versions < V2.135), IEC 1Ph 7.4kW Parent cable 7m incl. SIM (8EM1310-2EJ04-3GA2) (All versions < V2.135), IEC 1Ph 7.4kW Parent socket (8EM1310-2EH04-3GA1) (All versions < V2.135), IEC 1Ph 7.4kW Parent socket incl. SIM (8EM1310-2EH04-3GA2) (All versions < V2.135), IEC 1Ph 7.4kW Parent socket/ shutter (8EM1310-2EN04-3GA1) (All versions < V2.135), IEC 1Ph 7.4kW Parent socket/ shutter SIM (8EM1310-2EN04-3GA2) (All versions < V2.135), IEC 3Ph 22kW Child cable 7m (8EM1310-3EJ04-0GA0) (All versions < V2.135), IEC 3Ph 22kW Child socket (8EM1310-3EH04-0GA0) (All versions < V2.135), IEC 3Ph 22kW Child socket/ shutter (8EM1310-3EN04-0GA0) (All versions < V2.135), IEC 3Ph 22kW Parent cable 7m (8EM1310-3EJ04-3GA1) (All versions < V2.135), IEC 3Ph 22kW Parent cable 7m incl. SIM (8EM1310-3EJ04-3GA2) (All versions < V2.135), IEC 3Ph 22kW Parent socket (8EM1310-3EH04-3GA1) (All versions < V2.135), IEC 3Ph 22kW Parent socket incl. SIM (8EM1310-3EH04-3GA2) (All versions < V2.135), IEC 3Ph 22kW Parent socket/ shutter (8EM1310-3EN04-3GA1) (All versions < V2.135), IEC 3Ph 22kW Parent socket/ shutter SIM (8EM1310-3EN04-3GA2) (All versions < V2.135), IEC ERK 3Ph 22 kW Child cable 7m (8EM1310-3FJ04-0GA0) (All versions < V2.135), IEC ERK 3Ph 22 kW Child cable 7m (8EM1310-3FJ04-0GA1) (All versions < V2.135), IEC ERK 3Ph 22 kW Child cable 7m (8EM1310-3FJ04-0GA2) (All versions < V2.135), IEC ERK 3Ph 22 kW Child socket (8EM1310-3FH04-0GA0) (All versions < V2.135), IEC ERK 3Ph 22 kW Parent socket (8EM1310-3FH04-3GA1) (All versions < V2.135), IEC ERK 3Ph 22 kW Parent socket incl. SI (8EM1310-3FH04-3GA2) (All versions < V2.135), UL Commercial Cellular 48A NTEP (8EM1310-5HF14-1GA2) (All versions < V2.135), UL Commercial Child 40A w/ 15118 HW (8EM1310-4CF14-0GA0) (All versions < V2.135), UL Commercial Child 48A BA Compliant (8EM1315-5CG14-0GA0) (All versions < V2.135), UL Commercial Child 48A w/ 15118 HW (8EM1310-5CF14-0GA0) (All versions < V2.135), UL Commercial Parent 40A with Simcard (8EM1310-4CF14-1GA2) (All versions < V2.135), UL Commercial Parent 48A (USPS) (8EM1317-5CG14-1GA2) (All versions < V2.135), UL Commercial Parent 48A BA Compliant (8EM1315-5CG14-1GA2) (All versions < V2.135), UL Commercial Parent 48A with Simcard BA (8EM1310-5CF14-1GA2) (All versions < V2.135), UL Commercial Parent 48A, 15118, 25ft (8EM1310-5CG14-1GA1) (All versions < V2.135), UL Commercial Parent 48A, 15118, 25ft (8EM1314-5CG14-2FA2) (All versions < V2.135), UL Commercial Parent 48A, 15118, 25ft (8EM1315-5HG14-1GA2) (All versions < V2.135), UL Commercial Parent 48A,15118 25ft Sim (8EM1310-5CG14-1GA2) (All versions < V2.135), VersiCharge Blue™ 80A AC Cellular (8EM1315-7BG16-1FH2) (All versions < V2.135). Affected devices contain Modbus service enabled by default. This could allow an attacker connected to the same network to remotely control the EV charger.
CVE-2025-3194 2026-04-15 7.5 High
Versions of the package bigint-buffer from 0.0.0 are vulnerable to Buffer Overflow in the toBigIntLE() function. Attackers can exploit this to crash the application.
CVE-2025-31935 2026-04-15 6.2 Medium
Subnet Solutions PowerSYSTEM Center is affected by a mishandling of exceptional conditions vulnerability. Crafted data that is passed to the API may trigger an exception, resulting in a denial-of-service condition.
CVE-2025-31929 2026-04-15 4.2 Medium
A vulnerability has been identified in IEC 1Ph 7.4kW Child socket (8EM1310-2EH04-0GA0) (All versions), IEC 1Ph 7.4kW Child socket/ shutter (8EM1310-2EN04-0GA0) (All versions), IEC 1Ph 7.4kW Parent cable 7m (8EM1310-2EJ04-3GA1) (All versions), IEC 1Ph 7.4kW Parent cable 7m incl. SIM (8EM1310-2EJ04-3GA2) (All versions), IEC 1Ph 7.4kW Parent socket (8EM1310-2EH04-3GA1) (All versions), IEC 1Ph 7.4kW Parent socket incl. SIM (8EM1310-2EH04-3GA2) (All versions), IEC 1Ph 7.4kW Parent socket/ shutter (8EM1310-2EN04-3GA1) (All versions), IEC 1Ph 7.4kW Parent socket/ shutter SIM (8EM1310-2EN04-3GA2) (All versions), IEC 3Ph 22kW Child cable 7m (8EM1310-3EJ04-0GA0) (All versions), IEC 3Ph 22kW Child socket (8EM1310-3EH04-0GA0) (All versions), IEC 3Ph 22kW Child socket/ shutter (8EM1310-3EN04-0GA0) (All versions), IEC 3Ph 22kW Parent cable 7m (8EM1310-3EJ04-3GA1) (All versions), IEC 3Ph 22kW Parent cable 7m incl. SIM (8EM1310-3EJ04-3GA2) (All versions), IEC 3Ph 22kW Parent socket (8EM1310-3EH04-3GA1) (All versions), IEC 3Ph 22kW Parent socket incl. SIM (8EM1310-3EH04-3GA2) (All versions), IEC 3Ph 22kW Parent socket/ shutter (8EM1310-3EN04-3GA1) (All versions), IEC 3Ph 22kW Parent socket/ shutter SIM (8EM1310-3EN04-3GA2) (All versions), IEC ERK 3Ph 22 kW Child cable 7m (8EM1310-3FJ04-0GA0) (All versions), IEC ERK 3Ph 22 kW Child cable 7m (8EM1310-3FJ04-0GA1) (All versions), IEC ERK 3Ph 22 kW Child cable 7m (8EM1310-3FJ04-0GA2) (All versions), IEC ERK 3Ph 22 kW Child socket (8EM1310-3FH04-0GA0) (All versions), IEC ERK 3Ph 22 kW Parent socket (8EM1310-3FH04-3GA1) (All versions), IEC ERK 3Ph 22 kW Parent socket incl. SI (8EM1310-3FH04-3GA2) (All versions), UL Commercial Cellular 48A NTEP (8EM1310-5HF14-1GA2) (All versions), UL Commercial Child 40A w/ 15118 HW (8EM1310-4CF14-0GA0) (All versions), UL Commercial Child 48A BA Compliant (8EM1315-5CG14-0GA0) (All versions), UL Commercial Child 48A w/ 15118 HW (8EM1310-5CF14-0GA0) (All versions), UL Commercial Parent 40A with Simcard (8EM1310-4CF14-1GA2) (All versions), UL Commercial Parent 48A (USPS) (8EM1317-5CG14-1GA2) (All versions), UL Commercial Parent 48A BA Compliant (8EM1315-5CG14-1GA2) (All versions), UL Commercial Parent 48A with Simcard BA (8EM1310-5CF14-1GA2) (All versions), UL Commercial Parent 48A, 15118, 25ft (8EM1310-5CG14-1GA1) (All versions), UL Commercial Parent 48A, 15118, 25ft (8EM1314-5CG14-2FA2) (All versions), UL Commercial Parent 48A, 15118, 25ft (8EM1315-5HG14-1GA2) (All versions), UL Commercial Parent 48A,15118 25ft Sim (8EM1310-5CG14-1GA2) (All versions), UL Resi High End 40A w/15118 Hw (8EM1312-4CF18-0FA3) (All versions), UL Resi High End 48A w/15118 Hw (8EM1312-5CF18-0FA3) (All versions), VersiCharge Blue™ 80A AC Cellular (8EM1315-7BG16-1FH2) (All versions). Affected devices do not contain an Immutable Root of Trust in M0 Hardware. An attacker with physical access to the device could use this to execute arbitrary code.
CVE-2025-1066 2026-04-15 9.8 Critical
OpenPLC_V3 contains an arbitrary file upload vulnerability, which could be leveraged for malvertising or phishing campaigns.
CVE-2025-4076 2026-04-15 6.3 Medium
A vulnerability classified as critical has been found in LB-LINK BL-AC3600 up to 1.0.22. This affects the function easy_uci_set_option_string_0 of the file /cgi-bin/lighttpd.cgi of the component Password Handler. The manipulation of the argument routepwd leads to command injection. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2025-2345 2026-04-15 9.8 Critical
A vulnerability, which was classified as very critical, was found in IROAD Dash Cam X5 and Dash Cam X6 up to 20250308. This affects an unknown part. The manipulation leads to improper authorization. It is possible to initiate the attack remotely. The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2025-10496 2 Christophrado, Wordpress 2 Cookie Notice & Consent, Wordpress 2026-04-15 7.2 High
The Cookie Notice & Consent plugin for WordPress is vulnerable to Stored Cross-Site Scripting via the uuid parameter in all versions up to, and including, 1.6.5 due to insufficient input sanitization and output escaping. This makes it possible for unauthenticated attackers to inject arbitrary web scripts in pages that will execute whenever a user accesses an injected page.
CVE-2024-8775 1 Redhat 7 Ansible Automation Platform, Ansible Automation Platform Developer, Ansible Automation Platform Inside and 4 more 2026-04-15 5.5 Medium
A flaw was found in Ansible, where sensitive information stored in Ansible Vault files can be exposed in plaintext during the execution of a playbook. This occurs when using tasks such as include_vars to load vaulted variables without setting the no_log: true parameter, resulting in sensitive data being printed in the playbook output or logs. This can lead to the unintentional disclosure of secrets like passwords or API keys, compromising security and potentially allowing unauthorized access or actions.