| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| An issue was discovered on Renesas SmartBond DA14691, DA14695, DA14697, and DA14699 devices. The bootrom function responsible for validating the Flash Product Header directly uses a user-controllable size value (Length of Flash Config Section) to control a read from the QSPI device into a fixed sized buffer, resulting in a buffer overflow and execution of arbitrary code. |
| The WP Mobile Menu plugin for WordPress is vulnerable to unauthorized modification of data due to a missing capability check on the save_menu_item_icon function in all versions up to, and including, 2.8.4.4. This makes it possible for unauthenticated attackers to add the '_mobmenu_icon' post meta to arbitrary posts with an arbitrary (but sanitized) value. NOTE: Version 2.8.4.4 contains a partial fix for this vulnerability. |
| WebMail in Axigen 10.x before 10.3.3.62 allows XSS via the image attachment viewer. |
| In KDE libksieve before 23.03.80, kmanagesieve/session.cpp places a cleartext password in server logs because a username variable is accidentally given a password value. |
| NTFS-3G before 75dcdc2 has a use-after-free in ntfs_uppercase_mbs in libntfs-3g/unistr.c. NOTE: discussion suggests that exploitation would be challenging. |
| RedisBloom adds a set of probabilistic data structures to Redis. Starting in version 2.0.0 and prior to version 2.4.7 and 2.6.10, authenticated users can use the `CF.RESERVE` command to trigger a runtime assertion and termination of the Redis server process. The problem is fixed in RedisBloom 2.4.7 and 2.6.10. |
| A flaw was found in the Hive ClusterDeployments resource in OpenShift Dedicated. In certain conditions, this issue may allow a developer account on a Hive-enabled cluster to obtain cluster-admin privileges by executing arbitrary commands on the hive/hive-controllers pod. |
|
There is a function in AutomationDirect C-MORE EA9 HMI that allows an attacker to send a relative path in the URL without proper sanitizing of the content.
|
|
In AutomationDirect C-MORE EA9 HMI,
credentials used by the platform are stored as plain text on the device.
|
| A vulnerability has been identified in SIMATIC Energy Manager Basic (All versions < V7.5), SIMATIC Energy Manager PRO (All versions < V7.5), SIMATIC IPC DiagBase (All versions), SIMATIC IPC DiagMonitor (All versions), SIMIT V10 (All versions), SIMIT V11 (All versions < V11.1). Unified Automation .NET based OPC UA Server SDK before 3.2.2 used in Siemens products are affected by a similar vulnerability as documented in CVE-2023-27321 for the OPC Foundation UA .NET Standard implementation. A successful attack may lead to high load situation and memory exhaustion, and may block the server. |
| Dotmesh is a git-like command-line interface for capturing, organizing and sharing application states. In versions 0.8.1 and prior, the unsafe handling of symbolic links in an unpacking routine may
enable attackers to read and/or write to arbitrary locations outside the
designated target folder. The routine `untarFile` attempts to guard against creating symbolic links that point outside the directory a tar archive is extracted to. However, a malicious tarball first linking `subdir/parent` to `..` (allowed, because `subdir/..` falls within the archive root) and then linking `subdir/parent/escapes` to `..` results in a symbolic link pointing to the tarball’s parent directory, contrary to the routine’s goals. This issue may lead to arbitrary file write (with same permissions as the program running the unpack operation) if the attacker can control the archive file. Additionally, if the attacker has read access to the unpacked files, they may be able to read arbitrary system files the parent process has permissions to read. As of time of publication, no patch for this issue is available.
|
| Cross Site Scripting vulnerability found in Simplcommerce v.40734964b0811f3cbaf64b6dac261683d256f961 thru 3103357200c70b4767986544e01b19dbf11505a7 allows a remote attacker to execute arbitrary code via a crafted script to the search bar feature. |
| Driver Booster v10.6 was discovered to contain a buffer overflow via the Host parameter under the Customize proxy module. |
| An issue in Casa Systems NL1901ACV R6B032 allows a remote attacker to execute arbitrary code via the userName parameter of the add function. |
| A vulnerability has been identified in HiMed Cockpit 12 pro (J31032-K2017-H259) (All versions >= V11.5.1 < V11.6.2), HiMed Cockpit 14 pro+ (J31032-K2017-H435) (All versions >= V11.5.1 < V11.6.2), HiMed Cockpit 18 pro (J31032-K2017-H260) (All versions >= V11.5.1 < V11.6.2), HiMed Cockpit 18 pro+ (J31032-K2017-H436) (All versions >= V11.5.1 < V11.6.2). The Kiosk Mode of the affected devices contains a restricted desktop environment escape vulnerability. This could allow an unauthenticated local attacker to escape the restricted environment and gain access to the underlying operating system. |
| DIR-822 Rev. B Firmware v2.02KRB09 and DIR-822-CA Rev. B Firmware v2.03WWb01 suffer from a LAN-Side Unauthenticated Remote Code Execution (RCE) vulnerability elevated from HNAP Stack-Based Buffer Overflow. |
| RegEx Denial of Service in domain-suffix 1.0.8 allows attackers to crash the application via crafted input to the parse function. |
| s3-url-parser 1.0.3 is vulnerable to Denial of service via the regexes component. |
| Hikvision CSMP (Comprehensive Security Management Platform) iSecure Center through 2023-06-25 allows file upload via /center/api/files directory traversal, as exploited in the wild in 2024 and 2025. |
| In the Linux kernel, the following vulnerability has been resolved:
udf: Detect system inodes linked into directory hierarchy
When UDF filesystem is corrupted, hidden system inodes can be linked
into directory hierarchy which is an avenue for further serious
corruption of the filesystem and kernel confusion as noticed by syzbot
fuzzed images. Refuse to access system inodes linked into directory
hierarchy and vice versa. |