| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| CNCF K3s 1.32 before 1.32.4-rc1+k3s1 has a Kubernetes kubelet configuration change with the unintended consequence that, in some situations, ReadOnlyPort is set to 10255. For example, the default behavior of a K3s online installation might allow unauthenticated access to this port, exposing credentials. |
| fastify-swagger-ui is a Fastify plugin for serving Swagger UI. Prior to 2.1.0, the default configuration of `@fastify/swagger-ui` without `baseDir` set will lead to all files in the module's directory being exposed via http routes served by the module. The vulnerability is fixed in v2.1.0. Setting the `baseDir` option can also work around this vulnerability. |
| Donetick an open-source app for managing tasks and chores. Prior to version 0.1.44, the application uses JSON Web Tokens (JWT) for authentication, but the signing secret has a weak default value. While the responsibility is left to the system administrator to change it, this approach is inadequate. The vulnerability is proven by existence of the issue in the live version as well. This issue can result in full account takeover of any user. Version 0.1.44 contains a patch. |
| The CS5000 Fire Panel is vulnerable due to a default account that exists
on the panel. Even though it is possible to change this by SSHing into
the device, it has remained unchanged on every installed system
observed. This account is not root but holds high-level permissions that
could severely impact the device's operation if exploited. |
| A vulnerability has been identified in IEC 1Ph 7.4kW Child socket (8EM1310-2EH04-0GA0) (All versions < V2.135), IEC 1Ph 7.4kW Child socket/ shutter (8EM1310-2EN04-0GA0) (All versions < V2.135), IEC 1Ph 7.4kW Parent cable 7m (8EM1310-2EJ04-3GA1) (All versions < V2.135), IEC 1Ph 7.4kW Parent cable 7m incl. SIM (8EM1310-2EJ04-3GA2) (All versions < V2.135), IEC 1Ph 7.4kW Parent socket (8EM1310-2EH04-3GA1) (All versions < V2.135), IEC 1Ph 7.4kW Parent socket incl. SIM (8EM1310-2EH04-3GA2) (All versions < V2.135), IEC 1Ph 7.4kW Parent socket/ shutter (8EM1310-2EN04-3GA1) (All versions < V2.135), IEC 1Ph 7.4kW Parent socket/ shutter SIM (8EM1310-2EN04-3GA2) (All versions < V2.135), IEC 3Ph 22kW Child cable 7m (8EM1310-3EJ04-0GA0) (All versions < V2.135), IEC 3Ph 22kW Child socket (8EM1310-3EH04-0GA0) (All versions < V2.135), IEC 3Ph 22kW Child socket/ shutter (8EM1310-3EN04-0GA0) (All versions < V2.135), IEC 3Ph 22kW Parent cable 7m (8EM1310-3EJ04-3GA1) (All versions < V2.135), IEC 3Ph 22kW Parent cable 7m incl. SIM (8EM1310-3EJ04-3GA2) (All versions < V2.135), IEC 3Ph 22kW Parent socket (8EM1310-3EH04-3GA1) (All versions < V2.135), IEC 3Ph 22kW Parent socket incl. SIM (8EM1310-3EH04-3GA2) (All versions < V2.135), IEC 3Ph 22kW Parent socket/ shutter (8EM1310-3EN04-3GA1) (All versions < V2.135), IEC 3Ph 22kW Parent socket/ shutter SIM (8EM1310-3EN04-3GA2) (All versions < V2.135), IEC ERK 3Ph 22 kW Child cable 7m (8EM1310-3FJ04-0GA0) (All versions < V2.135), IEC ERK 3Ph 22 kW Child cable 7m (8EM1310-3FJ04-0GA1) (All versions < V2.135), IEC ERK 3Ph 22 kW Child cable 7m (8EM1310-3FJ04-0GA2) (All versions < V2.135), IEC ERK 3Ph 22 kW Child socket (8EM1310-3FH04-0GA0) (All versions < V2.135), IEC ERK 3Ph 22 kW Parent socket (8EM1310-3FH04-3GA1) (All versions < V2.135), IEC ERK 3Ph 22 kW Parent socket incl. SI (8EM1310-3FH04-3GA2) (All versions < V2.135), UL Commercial Cellular 48A NTEP (8EM1310-5HF14-1GA2) (All versions < V2.135), UL Commercial Child 40A w/ 15118 HW (8EM1310-4CF14-0GA0) (All versions < V2.135), UL Commercial Child 48A BA Compliant (8EM1315-5CG14-0GA0) (All versions < V2.135), UL Commercial Child 48A w/ 15118 HW (8EM1310-5CF14-0GA0) (All versions < V2.135), UL Commercial Parent 40A with Simcard (8EM1310-4CF14-1GA2) (All versions < V2.135), UL Commercial Parent 48A (USPS) (8EM1317-5CG14-1GA2) (All versions < V2.135), UL Commercial Parent 48A BA Compliant (8EM1315-5CG14-1GA2) (All versions < V2.135), UL Commercial Parent 48A with Simcard BA (8EM1310-5CF14-1GA2) (All versions < V2.135), UL Commercial Parent 48A, 15118, 25ft (8EM1310-5CG14-1GA1) (All versions < V2.135), UL Commercial Parent 48A, 15118, 25ft (8EM1314-5CG14-2FA2) (All versions < V2.135), UL Commercial Parent 48A, 15118, 25ft (8EM1315-5HG14-1GA2) (All versions < V2.135), UL Commercial Parent 48A,15118 25ft Sim (8EM1310-5CG14-1GA2) (All versions < V2.135), VersiCharge Blue™ 80A AC Cellular (8EM1315-7BG16-1FH2) (All versions < V2.135). Affected devices contain Modbus service enabled by default. This could allow an attacker connected to the same network to remotely control the EV charger. |
| Certain configuration available in the communication channel for encoders could expose sensitive data when reader configuration cards are programmed. This data could include credential and device administration keys. |
| Insecure default variable initialization of Intel(R) RealSense(TM) ID Solution F450 before version 2.6.0.74 may allow an unauthenticated user to potentially enable information disclosure via physical access. |
| In JetBrains RubyMine before 2025.1 remote Interpreter overwrote ports to listen on all interfaces |
| A flaw was found in Openshift. A pod with a DNSPolicy of "ClusterFirst" may incorrectly resolve the hostname based on a service provided. This flaw allows an attacker to supply an incorrect name with the DNS search policy, affecting confidentiality and availability. |
| In JetBrains TeamCity between 2022.10 and 2022.10.1 connecting to AWS using the "Default Credential Provider Chain" allowed TeamCity project administrators to access AWS resources normally limited to TeamCity system administrators. |
| In applyKeyguardFlags of NotificationShadeWindowControllerImpl.java, there is a possible way to observe the user's password on a secondary display due to an insecure default value. This could lead to local information disclosure with no additional execution privileges needed. User interaction is needed for exploitation.Product: AndroidVersions: Android-10 Android-11 Android-12 Android-12L Android-13Android ID: A-179725730 |
| Insecure default settings have been found in recorder products provided by Yokogawa Electric Corporation. The default setting of the authentication function is disabled on the affected products. Therefore, when connected to a network with default settings, anyone can access all functions related to settings and operations. As a result, an attacker can illegally manipulate and configure important data such as measured values and settings.
This issue affects GX10 / GX20 / GP10 / GP20 Paperless Recorders: R5.04.01 or earlier; GM Data Acquisition System: R5.05.01 or earlier; DX1000 / DX2000 / DX1000N Paperless Recorders: R4.21 or earlier; FX1000 Paperless Recorders: R1.31 or earlier; μR10000 / μR20000 Chart Recorders: R1.51 or earlier; MW100 Data Acquisition Units: All versions; DX1000T / DX2000T Paperless Recorders: All versions; CX1000 / CX2000 Paperless Recorders: All versions. |
| A vulnerability has been identified in SIMATIC PCS 7 V8.2 (All versions), SIMATIC PCS 7 V9.0 (All versions < V9.0 SP3 UC06), SIMATIC PCS 7 V9.1 (All versions < V9.1 SP1 UC01), SIMATIC WinCC Runtime Professional V16 and earlier (All versions), SIMATIC WinCC Runtime Professional V17 (All versions < V17 Upd4), SIMATIC WinCC V7.3 (All versions), SIMATIC WinCC V7.4 (All versions < V7.4 SP1 Update 21), SIMATIC WinCC V7.5 (All versions < V7.5 SP2 Update 8). A missing printer configuration on the host could allow an authenticated attacker to escape the WinCC Kiosk Mode. |
| A vulnerability in the ConfD CLI of Cisco Elastic Services Controllers could allow an authenticated, remote attacker to log in to an affected system as the admin user, aka an Insecure Default Administrator Credentials Vulnerability. More Information: CSCvc76661. Known Affected Releases: 2.2(9.76). |
| An issue was discovered on Siemens SICAM RTUs SM-2556 COM Modules with the firmware variants ENOS00, ERAC00, ETA2, ETLS00, MODi00, and DNPi00. The integrated web server (port 80/tcp) of the affected devices could allow unauthenticated remote attackers to execute arbitrary code on the affected device. |
| A vulnerability in Cisco Aironet 1830 Series and Cisco Aironet 1850 Series Access Points running Cisco Mobility Express Software could allow an unauthenticated, remote attacker to take complete control of an affected device. The vulnerability is due to the existence of default credentials for an affected device that is running Cisco Mobility Express Software, regardless of whether the device is configured as a master, subordinate, or standalone access point. An attacker who has layer 3 connectivity to an affected device could use Secure Shell (SSH) to log in to the device with elevated privileges. A successful exploit could allow the attacker to take complete control of the device. This vulnerability affects Cisco Aironet 1830 Series and Cisco Aironet 1850 Series Access Points that are running an 8.2.x release of Cisco Mobility Express Software prior to Release 8.2.111.0, regardless of whether the device is configured as a master, subordinate, or standalone access point. Release 8.2 was the first release of Cisco Mobility Express Software for next generation Cisco Aironet Access Points. Cisco Bug IDs: CSCva50691. |
| An issue was discovered in Schneider Electric Wonderware Historian 2014 R2 SP1 P01 and earlier. Wonderware Historian creates logins with default passwords, which can allow a malicious entity to compromise Historian databases. In some installation scenarios, resources beyond those created by Wonderware Historian may be compromised as well. |
| A vulnerability in Cisco Elastic Services Controllers could allow an authenticated, remote attacker to log in to an affected system as the Linux admin user, aka an Insecure Default Credentials Vulnerability. More Information: CSCvc76651. Known Affected Releases: 21.0.0. |
| A vulnerability in Cisco Ultra Services Framework Staging Server could allow an authenticated, remote attacker with access to the management network to log in as an admin user of the affected device, aka an Insecure Default Credentials Vulnerability. More Information: CSCvc76681. Known Affected Releases: 21.0.0. |
| A vulnerability in Cisco Ultra Services Framework Element Manager could allow an authenticated, remote attacker with access to the management network to log in as an admin or oper user of the affected device, aka an Insecure Default Credentials Vulnerability. More Information: CSCvc76699. Known Affected Releases: 21.0.0. |