| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| In the Linux kernel, the following vulnerability has been resolved:
fbdev: fix potential buffer overflow in do_register_framebuffer()
The current implementation may lead to buffer overflow when:
1. Unregistration creates NULL gaps in registered_fb[]
2. All array slots become occupied despite num_registered_fb < FB_MAX
3. The registration loop exceeds array bounds
Add boundary check to prevent registered_fb[FB_MAX] access. |
| In the Linux kernel, the following vulnerability has been resolved:
wifi: wilc1000: avoid buffer overflow in WID string configuration
Fix the following copy overflow warning identified by Smatch checker.
drivers/net/wireless/microchip/wilc1000/wlan_cfg.c:184 wilc_wlan_parse_response_frame()
error: '__memcpy()' 'cfg->s[i]->str' copy overflow (512 vs 65537)
This patch introduces size check before accessing the memory buffer.
The checks are base on the WID type of received data from the firmware.
For WID string configuration, the size limit is determined by individual
element size in 'struct wilc_cfg_str_vals' that is maintained in 'len' field
of 'struct wilc_cfg_str'. |
| A CWE-78 "Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) and EKI-6333AC-1GPO (<= v1.2.1). The source of the vulnerability relies on multiple parameters belonging to the "scan_ap" API which are not properly sanitized before being concatenated to OS level commands. |
| A CWE-78 "Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) and EKI-6333AC-1GPO (<= v1.2.1). The source of the vulnerability relies on multiple parameters belonging to the "snmp_apply" API which are not properly sanitized before being concatenated to OS level commands. |
| A CWE-78 "Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) and EKI-6333AC-1GPO (<= v1.2.1). The source of the vulnerability relies on multiple parameters belonging to the "certificate_file_remove" API which are not properly sanitized before being concatenated to OS level commands. |
| A CWE-78 "Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) and EKI-6333AC-1GPO (<= v1.2.1). The source of the vulnerability relies on multiple parameters belonging to the "connection_profile_apply" API which are not properly sanitized before being concatenated to OS level commands. |
| A CWE-78 "Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) and EKI-6333AC-1GPO (<= v1.2.1). The source of the vulnerability relies on multiple parameters belonging to the "mp_apply" API which are not properly sanitized before being concatenated to OS level commands. |
| A CWE-78 "Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) and EKI-6333AC-1GPO (<= v1.2.1). The source of the vulnerability relies on multiple parameters belonging to the "export_log" API which are not properly sanitized before being concatenated to OS level commands. |
| A CWE-78 "Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) and EKI-6333AC-1GPO (<= v1.2.1). The source of the vulnerability relies on multiple parameters belonging to the "lan_apply" API which are not properly sanitized before being concatenated to OS level commands. |
| route in main.c in Pico HTTP Server in C through f3b69a6 has an sprintf stack-based buffer overflow via a long URI, leading to remote code execution. |
| A CWE-78 "Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) and EKI-6333AC-1GPO (<= v1.2.1). The source of the vulnerability relies on multiple parameters belonging to the "applications_apply" API which are not properly sanitized before being concatenated to OS level commands. |
| A CWE-78 "Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) and EKI-6333AC-1GPO (<= v1.2.1). The source of the vulnerability relies on multiple parameters belonging to the "sta_log_htm" API which are not properly sanitized before being concatenated to OS level commands. |
| A CWE-78 "Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) and EKI-6333AC-1GPO (<= v1.2.1). The source of the vulnerability relies on multiple parameters belonging to the "basic_htm" API which are not properly sanitized before being concatenated to OS level commands. |
| A CWE-78 "Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) and EKI-6333AC-1GPO (<= v1.2.1). The source of the vulnerability relies on multiple parameters belonging to the "multiple_ssid_htm" API which are not properly sanitized before being concatenated to OS level commands. |
| A CWE-78 "Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) and EKI-6333AC-1GPO (<= v1.2.1). The vulnerability can be exploited by remote unauthenticated users capable of interacting with the default "edgserver" service enabled on the access point and malicious commands are executed with root privileges. No authentication is enabled on the service and the source of the vulnerability resides in processing code associated to the "cfg_cmd_set_eth_conf" operation. |
| A CWE-78 "Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) and EKI-6333AC-1GPO (<= v1.2.1). The vulnerability can be exploited by remote unauthenticated users capable of interacting with the default "edgserver" service enabled on the access point and malicious commands are executed with root privileges. No authentication is enabled on the service and the source of the vulnerability resides in processing code associated to the "wlan_scan" operation. |
| A CWE-78 "Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) and EKI-6333AC-1GPO (<= v1.2.1). The vulnerability can be exploited by remote unauthenticated users capable of interacting with the default "edgserver" service enabled on the access point and malicious commands are executed with root privileges. No authentication is enabled on the service and the source of the vulnerability resides in processing code associated to the "backup_config_to_utility" operation. |
| A CWE-78 "Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) and EKI-6333AC-1GPO (<= v1.2.1). The vulnerability can be exploited by remote unauthenticated users capable of interacting with the default "edgserver" service enabled on the access point and malicious commands are executed with root privileges. No authentication is enabled on the service and the source of the vulnerability resides in processing code associated to the "restore_config_from_utility" operation. |
| A CWE-78 "Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) and EKI-6333AC-1GPO (<= v1.2.1). The vulnerability can be exploited by remote unauthenticated users capable of interacting with the default "edgserver" service enabled on the access point and malicious commands are executed with root privileges. No authentication is enabled on the service and the source of the vulnerability resides in processing code associated to the "capture_packages" operation. |
| A CWE-306 "Missing Authentication for Critical Function" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) and EKI-6333AC-1GPO (<= v1.2.1). The vulnerability can be exploited by remote unauthenticated users capable of interacting with the default "edgserver" service enabled on the access point. |