| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| Missing authentication for critical function exists in Seiko Solutions SkyBridge series, which may allow a remote attacker to obtain or alter the setting information of the product or execute some critical functions without authentication, e.g., rebooting the product. Affected products and versions are as follows: SkyBridge MB-A200 firmware Ver. 01.00.05 and earlier, and SkyBridge BASIC MB-A130 firmware Ver. 1.4.1 and earlier |
| SnapCenter versions 4.7 prior to 4.7P2 and 4.8 prior to 4.8P1 are susceptible to a vulnerability which could allow a remote unauthenticated attacker to gain access as an admin user. |
| Missing Authentication for Critical Function in SICK Flexi Classic and Flexi Soft Gateways with Partnumbers 1042193, 1042964, 1044078, 1044072, 1044073, 1044074, 1099830, 1099832, 1127717, 1069070, 1112296, 1051432, 1102420, 1127487, 1121596, 1121597 allows an unauthenticated remote attacker to influence the availability of the device by changing the IP settings of the device via broadcasted UDP packets. |
| An unauthenticated remote attacker can get read access to files in the "/tmp" directory due to missing authentication. |
| EBM Technologies RISWEB's specific URL path is not properly controlled by permission, allowing attackers to browse specific pages and query sensitive data without login. |
| Microsoft Defender Security Feature Bypass Vulnerability |
| A authentication bypass using an alternate path or channel in Fortinet FortiClientWindows version 7.4.0, versions 7.2.4 through 7.2.0, versions 7.0.12 through 7.0.0, and 6.4.10 through 6.4.0 allows low privilege attacker to execute arbitrary code with high privilege via spoofed named pipe messages. |
| Authentication Bypass vulnerability in Hitachi Ops Center Common Services.This issue affects Hitachi Ops Center Common Services: from 10.9.3-00 before 11.0.2-01. |
| Even if the authentication fails for local service authentication, the requested command could still execute regardless of authentication status. |
| An authentication bypass in the admin web console of Ivanti CSA before 5.0.3 allows a remote unauthenticated attacker to gain administrative access |
| Missing Authentication for critical function vulnerability in HYPR Server allows Authentication Bypass when using Legacy APIs.This issue affects HYPR Server: before 8.0 (with enabled Legacy APIs)
|
| SAUTER Controls Nova 200–220 Series with firmware version 3.3-006 and prior and BACnetstac version 4.2.1 and prior allows the execution of commands without credentials. As Telnet and file transfer protocol (FTP) are the only protocols available for device management, an unauthorized user could access the system and modify the device configuration, which could result in the unauthorized user executing unrestricted malicious commands.
|
| LS ELECTRIC XBC-DN32U with operating system version 01.80 is missing authentication for its deletion command. This could allow an attacker to delete arbitrary files.
|
| LS ELECTRIC XBC-DN32U with operating system version 01.80 is missing authentication to perform critical functions to the PLC. This could allow an attacker to change the PLC's mode arbitrarily.
|
| LS ELECTRIC XBC-DN32U with operating system version 01.80 is missing authentication to create users on the PLC. This could allow an attacker to create and use an account with elevated privileges and take control of the device.
|
| Delta Electronics InfraSuite Device Master versions prior to 1.0.5 contain a vulnerability that could allow an attacker to achieve unauthenticated remote code execution in the context of an administrator. |
| Talend Data Catalog remote harvesting server before 8.0-20230413 contains a /upgrade endpoint that allows an unauthenticated WAR file to be deployed on the server. (A mitigation is that the remote harvesting server should be behind a firewall that only allows access to the Talend Data Catalog server.) |
| The hwPartsDFR module has a vulnerability in API calling verification. Successful exploitation of this vulnerability may affect device confidentiality. |
| The reminder module lacks an authentication mechanism for broadcasts received. Successful exploitation of this vulnerability may affect availability. |
| DHCP can add routes to a client’s routing table via the classless static route option (121). VPN-based security solutions that rely on routes to redirect traffic can be forced to leak traffic over the physical interface. An attacker on the same local network can read, disrupt, or possibly modify network traffic that was expected to be protected by the VPN. |