Export limit exceeded: 348295 CVEs match your query. Please refine your search to export 10,000 CVEs or fewer.
Export limit exceeded: 11573 CVEs match your query. Please refine your search to export 10,000 CVEs or fewer.
Export limit exceeded: 13943 CVEs match your query. Please refine your search to export 10,000 CVEs or fewer.
Export limit exceeded: 10249 CVEs match your query. Please refine your search to export 10,000 CVEs or fewer.
Search
Search Results (10249 CVEs found)
| CVE | Vendors | Products | Updated | CVSS v3.1 |
|---|---|---|---|---|
| CVE-2023-27976 | 1 Schneider-electric | 1 Ecostruxure Control Expert | 2025-02-05 | 8.8 High |
| A CWE-668: Exposure of Resource to Wrong Sphere vulnerability exists that could cause remote code execution when a valid user visits a malicious link provided through the web endpoints. Affected Products: EcoStruxure Control Expert (V15.1 and above) | ||||
| CVE-2023-29412 | 2 Microsoft, Schneider-electric | 7 Windows 10, Windows 11, Windows Server 2016 and 4 more | 2025-02-05 | 9.8 Critical |
| CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability exists that could cause remote code execution when manipulating internal methods through Java RMI interface. | ||||
| CVE-2022-32522 | 1 Schneider-electric | 1 Interactive Graphical Scada System | 2025-02-05 | 9.8 Critical |
| A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could cause a stack-based buffer overflow, potentially leading to remote code execution when an attacker sends specially crafted mathematically reduced data request messages. Affected Products: IGSS Data Server - IGSSdataServer.exe (Versions prior to V15.0.0.22170) | ||||
| CVE-2022-32523 | 1 Schneider-electric | 1 Interactive Graphical Scada System | 2025-02-05 | 9.8 Critical |
| A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could cause a stack-based buffer overflow, potentially leading to remote code execution when an attacker sends specially crafted online data request messages. Affected Products: IGSS Data Server - IGSSdataServer.exe (Versions prior to V15.0.0.22170) | ||||
| CVE-2022-32524 | 1 Schneider-electric | 1 Interactive Graphical Scada System | 2025-02-05 | 9.8 Critical |
| A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could cause a stack-based buffer overflow, potentially leading to remote code execution when an attacker sends specially crafted time reduced data messages. Affected Products: IGSS Data Server - IGSSdataServer.exe (Versions prior to V15.0.0.22170) | ||||
| CVE-2022-32525 | 1 Schneider-electric | 1 Interactive Graphical Scada System | 2025-02-05 | 9.8 Critical |
| A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could cause a stack-based buffer overflow, potentially leading to remote code execution when an attacker sends specially crafted alarm data messages. Affected Products: IGSS Data Server - IGSSdataServer.exe (Versions prior to V15.0.0.22170) | ||||
| CVE-2022-32526 | 1 Schneider-electric | 1 Interactive Graphical Scada System | 2025-02-05 | 9.8 Critical |
| A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could cause a stack-based buffer overflow, potentially leading to remote code execution when an attacker sends specially crafted setting value messages. Affected Products: IGSS Data Server - IGSSdataServer.exe (Versions prior to V15.0.0.22170) | ||||
| CVE-2022-32527 | 1 Schneider-electric | 1 Interactive Graphical Scada System | 2025-02-05 | 9.8 Critical |
| A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could cause a stack-based buffer overflow, potentially leading to remote code execution when an attacker sends specially crafted alarm cache data messages. Affected Products: IGSS Data Server - IGSSdataServer.exe (Versions prior to V15.0.0.22170) | ||||
| CVE-2022-32529 | 1 Schneider-electric | 1 Interactive Graphical Scada System | 2025-02-05 | 9.8 Critical |
| A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could cause a stack-based buffer overflow, potentially leading to remote code execution when an attacker sends specially crafted log data request messages. Affected Products: IGSS Data Server - IGSSdataServer.exe (Versions prior to V15.0.0.22170) | ||||
| CVE-2022-24324 | 1 Schneider-electric | 1 Interactive Graphical Scada System | 2025-02-05 | 9.8 Critical |
| A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could cause a stack-based buffer overflow potentially leading to remote code execution when an attacker sends a specially crafted message. Affected Products: IGSS Data Server - IGSSdataServer.exe (Versions prior to V15.0.0.22073) | ||||
| CVE-2022-2329 | 1 Schneider-electric | 1 Interactive Graphical Scada System | 2025-02-05 | 9.8 Critical |
| A CWE-190: Integer Overflow or Wraparound vulnerability exists that could cause heap-based buffer overflow, leading to denial of service and potentially remote code execution when an attacker sends multiple specially crafted messages. Affected Products: IGSS Data Server - IGSSdataServer.exe (Versions prior to V15.0.0.22073) | ||||
| CVE-2022-42971 | 2 Microsoft, Schneider-electric | 8 Windows 10, Windows 11, Windows 7 and 5 more | 2025-02-05 | 9.8 Critical |
| A CWE-434: Unrestricted Upload of File with Dangerous Type vulnerability exists that could cause remote code execution when the attacker uploads a malicious JSP file. Affected Products: APC Easy UPS Online Monitoring Software (Windows 7, 10, 11 & Windows Server 2016, 2019, 2022 - Versions prior to V2.5-GA), APC Easy UPS Online Monitoring Software (Windows 11, Windows Server 2019, 2022 - Versions prior to V2.5-GA-01-22261), Schneider Electric Easy UPS Online Monitoring Software (Windows 7, 10, 11 & Windows Server 2016, 2019, 2022 - Versions prior to V2.5-GS), Schneider Electric Easy UPS Online Monitoring Software (Windows 11, Windows Server 2019, 2022 - Versions prior to V2.5-GS-01-22261) | ||||
| CVE-2022-32512 | 1 Schneider-electric | 1 Canbrass | 2025-02-05 | 5.3 Medium |
| A CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists that could cause remote code execution when a command which exploits this vulnerability is utilized. Affected Products: CanBRASS (Versions prior to V7.5.1) | ||||
| CVE-2023-27978 | 1 Schneider-electric | 3 Custom Reports, Igss Dashboard, Igss Data Server | 2025-02-05 | 7.8 High |
| A CWE-502: Deserialization of Untrusted Data vulnerability exists in the Dashboard module that could cause an interpretation of malicious payload data, potentially leading to remote code execution when an attacker gets the user to open a malicious file. Affected Products: IGSS Data Server(IGSSdataServer.exe)(V16.0.0.23040 and prior), IGSS Dashboard(DashBoard.exe)(V16.0.0.23040 and prior), Custom Reports(RMS16.dll)(V16.0.0.23040 and prior). | ||||
| CVE-2023-27980 | 1 Schneider-electric | 3 Custom Reports, Igss Dashboard, Igss Data Server | 2025-02-05 | 8.8 High |
| A CWE-306: Missing Authentication for Critical Function vulnerability exists in the Data Server TCP interface that could allow the creation of a malicious report file in the IGSS project report directory, this could lead to remote code execution when a victim eventually opens the report. Affected Products: IGSS Data Server(IGSSdataServer.exe)(V16.0.0.23040 and prior), IGSS Dashboard(DashBoard.exe)(V16.0.0.23040 and prior), Custom Reports(RMS16.dll)(V16.0.0.23040 and prior) | ||||
| CVE-2023-27981 | 1 Schneider-electric | 3 Custom Reports, Igss Dashboard, Igss Data Server | 2025-02-05 | 7.8 High |
| A CWE-22: Improper Limitation of a Pathname to a Restricted Directory vulnerability exists in Custom Reports that could cause a remote code execution when a victim tries to open a malicious report. Affected Products: IGSS Data Server(IGSSdataServer.exe)(V16.0.0.23040 and prior), IGSS Dashboard(DashBoard.exe)(V16.0.0.23040 and prior), Custom Reports(RMS16.dll)(V16.0.0.23040 and prior). | ||||
| CVE-2023-27982 | 1 Schneider-electric | 3 Custom Reports, Igss Dashboard, Igss Data Server | 2025-02-05 | 8.8 High |
| A CWE-345: Insufficient Verification of Data Authenticity vulnerability exists in the Data Server that could cause manipulation of dashboard files in the IGSS project report directory, when an attacker sends specific crafted messages to the Data Server TCP port, this could lead to remote code execution when a victim eventually opens a malicious dashboard file. Affected Products: IGSS Data Server(IGSSdataServer.exe)(V16.0.0.23040 and prior), IGSS Dashboard(DashBoard.exe)(V16.0.0.23040 and prior), Custom Reports(RMS16.dll)(V16.0.0.23040 and prior). | ||||
| CVE-2023-27984 | 1 Schneider-electric | 3 Custom Reports, Igss Dashboard, Igss Data Server | 2025-02-05 | 7.8 High |
| A CWE-20: Improper Input Validation vulnerability exists in Custom Reports that could cause a macro to be executed, potentially leading to remote code execution when a user opens a malicious report file planted by an attacker. Affected Products: IGSS Data Server(IGSSdataServer.exe)(V16.0.0.23040 and prior), IGSS Dashboard(DashBoard.exe)(V16.0.0.23040 and prior), Custom Reports(RMS16.dll)(V16.0.0.23040 and prior). | ||||
| CVE-2023-29523 | 1 Xwiki | 1 Xwiki | 2025-02-05 | 10 Critical |
| XWiki Platform is a generic wiki platform offering runtime services for applications built on top of it. Any user who can edit their own user profile can execute arbitrary script macros including Groovy and Python macros that allow remote code execution including unrestricted read and write access to all wiki contents. The same vulnerability can also be exploited in other contexts where the `display` method on a document is used to display a field with wiki syntax, for example in applications created using `App Within Minutes`. This has been patched in XWiki 13.10.11, 14.4.8, 14.10.2 and 15.0RC1. There is no workaround apart from upgrading. | ||||
| CVE-2023-29519 | 1 Xwiki | 1 Xwiki | 2025-02-05 | 9.1 Critical |
| XWiki Platform is a generic wiki platform offering runtime services for applications built on top of it. A registered user can perform remote code execution leading to privilege escalation by injecting the proper code in the "property" field of an attachment selector, as a gadget of their own dashboard. Note that the vulnerability does not impact comments of a wiki. The vulnerability has been patched in XWiki 13.10.11, 14.4.8, 14.10.2, 15.0-rc-1. Users are advised to upgrade. There are no known workarounds for this vulnerability. | ||||