Export limit exceeded: 338524 CVEs match your query. Please refine your search to export 10,000 CVEs or fewer.
Export limit exceeded: 76046 CVEs match your query. Please refine your search to export 10,000 CVEs or fewer.
Search
Search Results (76046 CVEs found)
| CVE | Vendors | Products | Updated | CVSS v3.1 |
|---|---|---|---|---|
| CVE-2019-6858 | 1 Schneider-electric | 1 Msx Configurator | 2024-11-21 | 7.8 High |
| A CWE-427:Uncontrolled Search Path Element vulnerability exists in MSX Configurator (Software Version prior to V1.0.8.1), which could cause privilege escalation when injecting a malicious DLL. | ||||
| CVE-2019-6857 | 1 Schneider-electric | 58 140cpu65150, 140cpu65150 Firmware, 140cpu65160 and 55 more | 2024-11-21 | 7.5 High |
| A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in Modicon M580, Modicon M340, Modicon Quantum, Modicon Premium (see security notification for specific versions) which could cause a Denial of Service of the controller when reading specific memory blocks using Modbus TCP. | ||||
| CVE-2019-6856 | 1 Schneider-electric | 58 140cpu65150, 140cpu65150 Firmware, 140cpu65160 and 55 more | 2024-11-21 | 7.5 High |
| A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in Modicon M580, Modicon M340, Modicon Quantum, Modicon Premium (see security notification for specific versions) which could cause a Denial of Service when writing specific physical memory blocks using Modbus TCP. | ||||
| CVE-2019-6855 | 1 Schneider-electric | 44 Ecostruxure Control Expert, Modicon M340 Bmxp341000, Modicon M340 Bmxp341000 Firmware and 41 more | 2024-11-21 | 7.3 High |
| Incorrect Authorization vulnerability exists in EcoStruxure Control Expert (all versions prior to 14.1 Hot Fix), Unity Pro (all versions), Modicon M340 (all versions prior to V3.20) , and Modicon M580 (all versions prior to V3.10), which could cause a bypass of the authentication process between EcoStruxure Control Expert and the M340 and M580 controllers. | ||||
| CVE-2019-6854 | 1 Schneider-electric | 1 Clearscada | 2024-11-21 | 7.8 High |
| A CWE-287: Improper Authentication vulnerability exists in a folder within EcoStruxure Geo SCADA Expert (ClearSCADA) -with initial releases before 1 January 2019- which could cause a low privilege user to delete or modify database, setting or certificate files. Those users must have access to the file system of that operating system to exploit this vulnerability. Affected versions in current support includes ClearSCADA 2017 R3, ClearSCADA 2017 R2, and ClearSCADA 2017. | ||||
| CVE-2019-6852 | 1 Schneider-electric | 20 140 Cpu6x, 140 Cpu6x Firmware, 140 Noc 77101 and 17 more | 2024-11-21 | 7.5 High |
| A CWE-200: Information Exposure vulnerability exists in Modicon Controllers (M340 CPUs, M340 communication modules, Premium CPUs, Premium communication modules, Quantum CPUs, Quantum communication modules - see security notification for specific versions), which could cause the disclosure of FTP hardcoded credentials when using the Web server of the controller on an unsecure network. | ||||
| CVE-2019-6851 | 1 Schneider-electric | 46 Modicon M340, Modicon M340 Firmware, Modicon M580 and 43 more | 2024-11-21 | 7.5 High |
| A CWE-538: File and Directory Information Exposure vulnerability exists in Modicon M580, Modicon M340, Modicon Premium , Modicon Quantum (all firmware versions), which could cause the disclosure of information from the controller when using TFTP protocol. | ||||
| CVE-2019-6850 | 1 Schneider-electric | 6 Modicon Bmenoc 0311, Modicon Bmenoc 0311 Firmware, Modicon Bmenoc 0321 and 3 more | 2024-11-21 | 7.5 High |
| A CWE-200: Information Exposure vulnerability exists in Modicon M580, Modicon BMENOC 0311, and Modicon BMENOC 0321, which could cause the disclosure of sensitive information when reading specific registers with the REST API of the controller/communication module. | ||||
| CVE-2019-6849 | 1 Schneider-electric | 6 Modicon Bmenoc 0311, Modicon Bmenoc 0311 Firmware, Modicon Bmenoc 0321 and 3 more | 2024-11-21 | 7.5 High |
| A CWE-200: Information Exposure vulnerability exists in Modicon M580, Modicon BMENOC 0311, and Modicon BMENOC 0321, which could cause the disclosure of sensitive information when using specific Modbus services provided by the REST API of the controller/communication module. | ||||
| CVE-2019-6848 | 1 Schneider-electric | 6 Modicon Bmenoc 0311, Modicon Bmenoc 0311 Firmware, Modicon Bmenoc 0321 and 3 more | 2024-11-21 | 8.6 High |
| A CWE-755: Improper Handling of Exceptional Conditions vulnerability exists in Modicon M580 CPU (BMEx58*) and Modicon M580 communication module (BMENOC0311, BMENOC0321) (see notification for version info), which could cause a Denial of Service attack on the PLC when sending specific data on the REST API of the controller/communication module. | ||||
| CVE-2019-6845 | 1 Schneider-electric | 46 Modicon M340, Modicon M340 Firmware, Modicon M580 and 43 more | 2024-11-21 | 7.5 High |
| A CWE-319: Cleartext Transmission of Sensitive Information vulnerability exists in Modicon M580, Modicon M340, Modicon Premium , Modicon Quantum (all firmware versions), which could cause the disclosure of information when transferring applications to the controller using Modbus TCP protocol. | ||||
| CVE-2019-6839 | 1 Schneider-electric | 8 Meg6260-0410, Meg6260-0410 Firmware, Meg6260-0415 and 5 more | 2024-11-21 | 8.8 High |
| A CWE-434: Unrestricted Upload of File with Dangerous Type vulnerability exists in U.motion Server (MEG6501-0001 - U.motion KNX server, MEG6501-0002 - U.motion KNX Server Plus, MEG6260-0410 - U.motion KNX Server Plus, Touch 10, MEG6260-0415 - U.motion KNX Server Plus, Touch 15), which could allow a user with low privileges to upload a rogue file. | ||||
| CVE-2019-6836 | 1 Schneider-electric | 8 Meg6260-0410, Meg6260-0410 Firmware, Meg6260-0415 and 5 more | 2024-11-21 | 7.5 High |
| A CWE-863: Incorrect Authorization vulnerability exists in U.motion Server (MEG6501-0001 - U.motion KNX server, MEG6501-0002 - U.motion KNX Server Plus, MEG6260-0410 - U.motion KNX Server Plus, Touch 10, MEG6260-0415 - U.motion KNX Server Plus, Touch 15), which could allow the file system to access the wrong file. | ||||
| CVE-2019-6834 | 1 Schneider-electric | 1 Software Update | 2024-11-21 | 7.3 High |
| A CWE-502: Deserialization of Untrusted Data vulnerability exists which could allow an attacker to execute arbitrary code on the targeted system with SYSTEM privileges when placing a malicious user to be authenticated for this vulnerability to be successfully exploited. Affected Product: Schneider Electric Software Update (SESU) SUT Service component (V2.1.1 to V2.3.0) | ||||
| CVE-2019-6832 | 1 Schneider-electric | 4 Lss100100, Lss100200, Spacelynk Firmware and 1 more | 2024-11-21 | 8.3 High |
| A CWE-287: Authentication vulnerability exists in spaceLYnk (all versions before 2.4.0) and Wiser for KNX (all versions before 2.4.0 - formerly known as homeLYnk), which could cause loss of control when an attacker bypasses the authentication. | ||||
| CVE-2019-6831 | 1 Schneider-electric | 2 Bmxnor0200h, Bmxnor0200h Firmware | 2024-11-21 | 8.6 High |
| A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in BMXNOR0200H Ethernet / Serial RTU module (all firmware versions), which could cause disconnection of active connections when an unusually high number of IEC 60870- 5-104 packets are received by the module on port 2404/TCP. | ||||
| CVE-2019-6829 | 1 Schneider-electric | 4 Modicon M340, Modicon M340 Firmware, Modicon M580 and 1 more | 2024-11-21 | 7.5 High |
| A CWE-248: Uncaught Exception vulnerability exists in Modicon M580 (firmware version prior to V2.90) and Modicon M340 (firmware version prior to V3.10), which could cause a possible denial of service when writing to specific memory addresses in the controller over Modbus. | ||||
| CVE-2019-6828 | 1 Schneider-electric | 8 Modicon M340, Modicon M340 Firmware, Modicon M580 and 5 more | 2024-11-21 | 7.5 High |
| A CWE-248: Uncaught Exception vulnerability exists Modicon M580 (firmware version prior to V2.90), Modicon M340 (firmware version prior to V3.10), Modicon Premium (all versions), and Modicon Quantum (all versions), which could cause a possible denial of service when reading specific coils and registers in the controller over Modbus. | ||||
| CVE-2019-6827 | 1 Schneider-electric | 1 Interactive Graphical Scada System | 2024-11-21 | 7.8 High |
| A CWE-787: Out-of-bounds Write vulnerability exists in Interactive Graphical SCADA System (IGSS), Version 14 and prior, which could cause a software crash when data in the mdb database is manipulated. | ||||
| CVE-2019-6826 | 1 Schneider-electric | 1 Somachine Hvac | 2024-11-21 | 7.8 High |
| A CWE-426: Untrusted Search Path vulnerability exists in SoMachine HVAC v2.4.1 and earlier versions, which could cause arbitrary code execution on the system running SoMachine HVAC when a malicious DLL library is loaded by the product. | ||||