Export limit exceeded: 338063 CVEs match your query. Please refine your search to export 10,000 CVEs or fewer.

Export limit exceeded: 75898 CVEs match your query. Please refine your search to export 10,000 CVEs or fewer.

Search

Search Results (75898 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2019-19316 1 Hashicorp 1 Terraform 2024-11-21 7.5 High
When using the Azure backend with a shared access signature (SAS), Terraform versions prior to 0.12.17 may transmit the token and state snapshot using cleartext HTTP.
CVE-2019-19315 1 Nalpeiron 1 Licensing Service 2024-11-21 7.1 High
NLSSRV32.EXE in Nalpeiron Licensing Service 7.3.4.0, as used with Nitro PDF and other products, allows Elevation of Privilege via the \\.\mailslot\nlsX86ccMailslot mailslot.
CVE-2019-19314 1 Gitlab 1 Gitlab 2024-11-21 7.5 High
GitLab EE 8.4 through 12.5, 12.4.3, and 12.3.6 stored several tokens in plaintext.
CVE-2019-19313 1 Gitlab 1 Gitlab 2024-11-21 7.5 High
GitLab EE 12.3 through 12.5, 12.4.3, and 12.3.6 allows Denial of Service. Certain characters were making it impossible to create, edit, or view issues and commits.
CVE-2019-19301 1 Siemens 26 Scalance X-200irt, Scalance X-200irt Firmware, Scalance X-200irt Pro and 23 more 2024-11-21 7.5 High
A vulnerability has been identified in SCALANCE X200-4P IRT, SCALANCE X201-3P IRT, SCALANCE X201-3P IRT PRO, SCALANCE X202-2IRT, SCALANCE X202-2P IRT, SCALANCE X202-2P IRT PRO, SCALANCE X204-2, SCALANCE X204-2FM, SCALANCE X204-2LD, SCALANCE X204-2LD TS, SCALANCE X204-2TS, SCALANCE X204IRT, SCALANCE X204IRT PRO, SCALANCE X206-1, SCALANCE X206-1LD, SCALANCE X208, SCALANCE X208PRO, SCALANCE X212-2, SCALANCE X212-2LD, SCALANCE X216, SCALANCE X224, SCALANCE X302-7 EEC (230V, coated), SCALANCE X302-7 EEC (230V), SCALANCE X302-7 EEC (24V, coated), SCALANCE X302-7 EEC (24V), SCALANCE X302-7 EEC (2x 230V, coated), SCALANCE X302-7 EEC (2x 230V), SCALANCE X302-7 EEC (2x 24V, coated), SCALANCE X302-7 EEC (2x 24V), SCALANCE X304-2FE, SCALANCE X306-1LD FE, SCALANCE X307-2 EEC (230V, coated), SCALANCE X307-2 EEC (230V), SCALANCE X307-2 EEC (24V, coated), SCALANCE X307-2 EEC (24V), SCALANCE X307-2 EEC (2x 230V, coated), SCALANCE X307-2 EEC (2x 230V), SCALANCE X307-2 EEC (2x 24V, coated), SCALANCE X307-2 EEC (2x 24V), SCALANCE X307-3, SCALANCE X307-3, SCALANCE X307-3LD, SCALANCE X307-3LD, SCALANCE X308-2, SCALANCE X308-2, SCALANCE X308-2LD, SCALANCE X308-2LD, SCALANCE X308-2LH, SCALANCE X308-2LH, SCALANCE X308-2LH+, SCALANCE X308-2LH+, SCALANCE X308-2M, SCALANCE X308-2M, SCALANCE X308-2M PoE, SCALANCE X308-2M PoE, SCALANCE X308-2M TS, SCALANCE X308-2M TS, SCALANCE X310, SCALANCE X310, SCALANCE X310FE, SCALANCE X310FE, SCALANCE X320-1 FE, SCALANCE X320-1-2LD FE, SCALANCE X408-2, SCALANCE XF201-3P IRT, SCALANCE XF202-2P IRT, SCALANCE XF204, SCALANCE XF204-2, SCALANCE XF204-2BA IRT, SCALANCE XF204IRT, SCALANCE XF206-1, SCALANCE XF208, SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M TS (24V), SCALANCE XR324-12M TS (24V), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M PoE (230V, ports on front), SCALANCE XR324-4M PoE (230V, ports on rear), SCALANCE XR324-4M PoE (24V, ports on front), SCALANCE XR324-4M PoE (24V, ports on rear), SCALANCE XR324-4M PoE TS (24V, ports on front), SIMATIC CP 343-1 Advanced, SIMATIC CP 442-1 RNA, SIMATIC CP 443-1, SIMATIC CP 443-1, SIMATIC CP 443-1 Advanced, SIMATIC CP 443-1 RNA, SIMATIC RF180C, SIMATIC RF182C, SIPLUS NET CP 343-1 Advanced, SIPLUS NET CP 443-1, SIPLUS NET CP 443-1 Advanced, SIPLUS NET SCALANCE X308-2. The VxWorks-based Profinet TCP Stack can be forced to make very expensive calls for every incoming packet which can lead to a denial of service.
CVE-2019-19299 1 Siemens 1 Sinvr\/sivms Video Server 2024-11-21 7.5 High
A vulnerability has been identified in SiNVR/SiVMS Video Server (All versions < V5.0.0), SiNVR/SiVMS Video Server (All versions >= V5.0.0 < V5.0.2), SiNVR/SiVMS Video Server (All versions >= V5.0.2). The streaming service (default port 5410/tcp) of the SiVMS/SiNVR Video Server applies weak cryptography when exposing device (camera) passwords. This could allow an unauthenticated remote attacker to read and decrypt the passwords and conduct further attacks.
CVE-2019-19298 1 Siemens 1 Sinvr\/sivms Video Server 2024-11-21 7.5 High
A vulnerability has been identified in SiNVR/SiVMS Video Server (All versions < V5.0.0), SiNVR/SiVMS Video Server (All versions >= V5.0.0 < V5.0.2). The streaming service (default port 5410/tcp) of the SiVMS/SiNVR Video Server contains a input validation vulnerability, that could allow an unauthenticated remote attacker to cause a Denial-of-Service condition by sending malformed HTTP requests.
CVE-2019-19297 1 Siemens 2 Sinvr 3 Central Control Server, Sinvr 3 Video Server 2024-11-21 7.5 High
A vulnerability has been identified in SiNVR/SiVMS Video Server (All versions < V5.0.0). The streaming service (default port 5410/tcp) of the SiVMS/SiNVR Video Server contains a path traversal vulnerability, that could allow an unauthenticated remote attacker to access and download arbitrary files from the server.
CVE-2019-19292 1 Siemens 2 Sinvr 3 Central Control Server, Sinvr 3 Video Server 2024-11-21 8.8 High
A vulnerability has been identified in Control Center Server (CCS) (All versions < V1.5.0). The Control Center Server (CCS) contains an SQL injection vulnerability in its XML-based communication protocol as provided by default on ports 5444/tcp and 5440/tcp. An authenticated remote attacker could exploit this vulnerability to read or modify the CCS database and potentially execute administrative database operations or operating system commands.
CVE-2019-19289 1 Siemens 1 Xhq 2024-11-21 8.8 High
A vulnerability has been identified in XHQ (All Versions < 6.1). The web interface could allow a Cross-Site Request Forgery (CSRF) attack if an unsuspecting user is tricked into accessing a malicious link.
CVE-2019-19286 1 Siemens 1 Xhq 2024-11-21 7.2 High
A vulnerability has been identified in XHQ (All Versions < 6.1). The web interface could allow SQL injection attacks if an attacker is able to modify content of particular web pages.
CVE-2019-19282 1 Siemens 6 Openpcs 7, Simatic Batch, Simatic Net Pc and 3 more 2024-11-21 7.5 High
A vulnerability has been identified in OpenPCS 7 V8.1 (All versions), OpenPCS 7 V8.2 (All versions), OpenPCS 7 V9.0 (All versions < V9.0 Upd3), SIMATIC BATCH V8.1 (All versions), SIMATIC BATCH V8.2 (All versions < V8.2 Upd12), SIMATIC BATCH V9.0 (All versions < V9.0 SP1 Upd5), SIMATIC NET PC Software V14 (All versions < V14 SP1 Update 14), SIMATIC NET PC Software V15 (All versions), SIMATIC NET PC Software V16 (All versions < V16 Update 1), SIMATIC PCS 7 V8.1 (All versions), SIMATIC PCS 7 V8.2 (All versions), SIMATIC PCS 7 V9.0 (All versions < V9.0 SP3), SIMATIC Route Control V8.1 (All versions), SIMATIC Route Control V8.2 (All versions), SIMATIC Route Control V9.0 (All versions < V9.0 Upd4), SIMATIC WinCC (TIA Portal) V13 (All versions < V13 SP2), SIMATIC WinCC (TIA Portal) V14 (All versions < V14 SP1 Update 10), SIMATIC WinCC (TIA Portal) V15.1 (All versions < V15.1 Update 5), SIMATIC WinCC (TIA Portal) V16 (All versions < V16 Update 1), SIMATIC WinCC V7.3 (All versions), SIMATIC WinCC V7.4 (All versions < V7.4 SP1 Update 14), SIMATIC WinCC V7.5 (All versions < V7.5 SP1 Update 1). Through specially crafted messages, when encrypted communication is enabled, an attacker with network access could use the vulnerability to compromise the availability of the system by causing a Denial-of-Service condition. Successful exploitation requires no system privileges and no user interaction.
CVE-2019-19281 1 Siemens 28 Simatic Et 200sp Open Controller Cpu 1515sp Pc2, Simatic Et 200sp Open Controller Cpu 1515sp Pc2 Firmware, Simatic S7-1500 Cpu 1507s and 25 more 2024-11-21 7.5 High
A vulnerability has been identified in SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions >= V2.5 and < V20.8), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions >= V2.5 and < V2.8), SIMATIC S7-1500 Software Controller (All versions >= V2.5 and < V20.8). Affected devices contain a vulnerability that allows an unauthenticated attacker to trigger a Denial-of-Service condition. The vulnerability can be triggered if specially crafted UDP packets are sent to the device. The security vulnerability could be exploited by an attacker with network access to the affected systems. Successful exploitation requires no system privileges and no user interaction. An attacker could use the vulnerability to compromise the device availability.
CVE-2019-19279 1 Siemens 2 Siprotec 4, Siprotec Compact 2024-11-21 7.5 High
A vulnerability has been identified in SIPROTEC 4 and SIPROTEC Compact relays equipped with EN100 Ethernet communication modules (All versions). Specially crafted packets sent to port 50000/UDP of the EN100 Ethernet communication modules could cause a Denial-of-Service of the affected device. A manual reboot is required to recover the service of the device. At the time of advisory publication no public exploitation of this security vulnerability was known to Siemens.
CVE-2019-19275 1 Python 1 Typed Ast 2024-11-21 7.5 High
typed_ast 1.3.0 and 1.3.1 has an ast_for_arguments out-of-bounds read. An attacker with the ability to cause a Python interpreter to parse Python source (but not necessarily execute it) may be able to crash the interpreter process. This could be a concern, for example, in a web-based service that parses (but does not execute) Python code. (This issue also affected certain Python 3.8.0-alpha prereleases.)
CVE-2019-19274 1 Python 1 Typed Ast 2024-11-21 7.5 High
typed_ast 1.3.0 and 1.3.1 has a handle_keywordonly_args out-of-bounds read. An attacker with the ability to cause a Python interpreter to parse Python source (but not necessarily execute it) may be able to crash the interpreter process. This could be a concern, for example, in a web-based service that parses (but does not execute) Python code. (This issue also affected certain Python 3.8.0-alpha prereleases.)
CVE-2019-19273 2 Google, Samsung 5 Android, Exynos 8895, Galaxy Note8 and 2 more 2024-11-21 7.8 High
On Samsung mobile devices with O(8.0) and P(9.0) software and an Exynos 8895 chipset, RKP (aka the Samsung Hypervisor EL2 implementation) allows arbitrary memory write operations. The Samsung ID is SVE-2019-16265.
CVE-2019-19272 1 Proftpd 1 Proftpd 2024-11-21 7.5 High
An issue was discovered in tls_verify_crl in ProFTPD before 1.3.6. Direct dereference of a NULL pointer (a variable initialized to NULL) leads to a crash when validating the certificate of a client connecting to the server in a TLS client/server mutual-authentication setup.
CVE-2019-19271 1 Proftpd 1 Proftpd 2024-11-21 7.5 High
An issue was discovered in tls_verify_crl in ProFTPD before 1.3.6. A wrong iteration variable, used when checking a client certificate against CRL entries (installed by a system administrator), can cause some CRL entries to be ignored, and can allow clients whose certificates have been revoked to proceed with a connection to the server.
CVE-2019-19270 2 Fedoraproject, Proftpd 2 Fedora, Proftpd 2024-11-21 7.5 High
An issue was discovered in tls_verify_crl in ProFTPD through 1.3.6b. Failure to check for the appropriate field of a CRL entry (checking twice for subject, rather than once for subject and once for issuer) prevents some valid CRLs from being taken into account, and can allow clients whose certificates have been revoked to proceed with a connection to the server.