Export limit exceeded: 75601 CVEs match your query. Please refine your search to export 10,000 CVEs or fewer.
Search
Search Results (75601 CVEs found)
| CVE | Vendors | Products | Updated | CVSS v3.1 |
|---|---|---|---|---|
| CVE-2019-13563 | 1 Dlink | 2 Dir-655, Dir-655 Firmware | 2024-11-21 | 8.8 High |
| D-Link DIR-655 C devices before 3.02B05 BETA03 allow CSRF for the entire management console. | ||||
| CVE-2019-13559 | 1 Ge | 1 Mark Vie Controll System | 2024-11-21 | 7.8 High |
| GE Mark VIe Controller is shipped with pre-configured hard-coded credentials that may allow root-user access to the controller. A limited application of the affected product may ship without setup and configuration instructions immediately available to the end user. The bulk of controllers go into applications requiring the GE commissioning engineer to change default configurations during the installation process. GE recommends that users reset controller passwords during installation in the operating environment. | ||||
| CVE-2019-13556 | 1 Advantech | 1 Webaccess | 2024-11-21 | 8.8 High |
| In WebAccess versions 8.4.1 and prior, multiple stack-based buffer overflow vulnerabilities are caused by a lack of proper validation of the length of user-supplied data. Exploitation of these vulnerabilities may allow remote code execution. | ||||
| CVE-2019-13554 | 1 Ge | 1 Mark Vie Control System | 2024-11-21 | 8.8 High |
| GE Mark VIe Controller has an unsecured Telnet protocol that may allow a user to create an authenticated session using generic default credentials. GE recommends that users disable the Telnet service. | ||||
| CVE-2019-13552 | 1 Advantech | 1 Webaccess | 2024-11-21 | 8.8 High |
| In WebAccess versions 8.4.1 and prior, multiple command injection vulnerabilities are caused by a lack of proper validation of user-supplied data and may allow arbitrary file deletion and remote code execution. | ||||
| CVE-2019-13549 | 2 Carel, Rittal | 2 Pcoweb Firmware, Chiller Sk 3232 | 2024-11-21 | 7.5 High |
| Rittal Chiller SK 3232-Series web interface as built upon Carel pCOWeb firmware A1.5.3 – B1.2.4. The authentication mechanism on affected systems does not provide a sufficient level of protection against unauthorized configuration changes. Primary operations, namely turning the cooling unit on and off and setting the temperature set point, can be modified without authentication. | ||||
| CVE-2019-13545 | 1 Hornerautomation | 1 Cscape | 2024-11-21 | 7.8 High |
| In Horner Automation Cscape 9.90 and prior, improper validation of data may cause the system to write outside the intended buffer area, which may allow arbitrary code execution. | ||||
| CVE-2019-13544 | 1 Deltaww | 1 Tpeditor | 2024-11-21 | 7.8 High |
| Delta Electronics TPEditor, Versions 1.94 and prior. Multiple out-of-bounds write vulnerabilities may be exploited by processing specially crafted project files, which may allow remote code execution. | ||||
| CVE-2019-13541 | 1 Hornerautomation | 1 Cscape | 2024-11-21 | 7.8 High |
| In Horner Automation Cscape 9.90 and prior, an improper input validation vulnerability has been identified that may be exploited by processing files lacking user input validation. This may allow an attacker to access information and remotely execute arbitrary code. | ||||
| CVE-2019-13540 | 1 Deltaww | 1 Tpeditor | 2024-11-21 | 7.8 High |
| Delta Electronics TPEditor, Versions 1.94 and prior. Multiple stack-based buffer overflow vulnerabilities may be exploited by processing specially crafted project files, which may allow an attacker to remotely execute arbitrary code. | ||||
| CVE-2019-13538 | 1 Codesys | 1 Codesys | 2024-11-21 | 8.6 High |
| 3S-Smart Software Solutions GmbH CODESYS V3 Library Manager, all versions prior to 3.5.16.0, allows the system to display active library content without checking its validity, which may allow the contents of manipulated libraries to be displayed or executed. The issue also exists for source libraries, but 3S-Smart Software Solutions GmbH strongly recommends distributing compiled libraries only. | ||||
| CVE-2019-13537 | 1 Aveva | 2 Iec870ip, Iec870ip Firmware | 2024-11-21 | 7.5 High |
| The IEC870IP driver for AVEVA’s Vijeo Citect and Citect SCADA and Schneider Electric’s Power SCADA Operation has a buffer overflow vulnerability that could result in a server-side crash. | ||||
| CVE-2019-13536 | 1 Deltaww | 1 Tpeditor | 2024-11-21 | 7.8 High |
| Delta Electronics TPEditor, Versions 1.94 and prior. Multiple heap-based buffer overflow vulnerabilities may be exploited by processing specially crafted project files, which may allow an attacker to remotely execute arbitrary code. | ||||
| CVE-2019-13534 | 1 Philips | 19 865240, 865241, 865242 and 16 more | 2024-11-21 | 7.2 High |
| Philips IntelliVue WLAN, portable patient monitors, WLAN Version A, Firmware A.03.09, WLAN Version A, Firmware A.03.09, Part #: M8096-67501, WLAN Version B, Firmware A.01.09, Part #: N/A (Replaced by Version C) and WLAN Version B, Firmware A.01.09, Part #: N/A (Replaced by Version C). The product downloads source code or an executable from a remote location and executes the code without sufficiently verifying the origin and integrity of the code. | ||||
| CVE-2019-13533 | 1 Omron | 2 Plc Cj Firmware, Plc Cs Firmware | 2024-11-21 | 8.1 High |
| In Omron PLC CJ series, all versions, and Omron PLC CS series, all versions, an attacker could monitor traffic between the PLC and the controller and replay requests that could result in the opening and closing of industrial valves. | ||||
| CVE-2019-13532 | 1 Codesys | 13 Control For Beaglebone, Control For Empc-a\/imx6, Control For Iot2000 and 10 more | 2024-11-21 | 7.5 High |
| CODESYS V3 web server, all versions prior to 3.5.14.10, allows an attacker to send specially crafted http or https requests which may allow access to files outside the restricted working directory of the controller. | ||||
| CVE-2019-13530 | 1 Philips | 19 865240, 865241, 865242 and 16 more | 2024-11-21 | 7.2 High |
| Philips IntelliVue WLAN, portable patient monitors, WLAN Version A, Firmware A.03.09, WLAN Version A, Firmware A.03.09, Part #: M8096-67501, WLAN Version B, Firmware A.01.09, Part #: N/A (Replaced by Version C) and WLAN Version B, Firmware A.01.09, Part #: N/A (Replaced by Version C). An attacker can use these credentials to login via ftp and upload a malicious firmware. | ||||
| CVE-2019-13529 | 1 Sma | 2 Sunny Webbox, Sunny Webbox Firmware | 2024-11-21 | 8.8 High |
| An attacker could send a malicious link to an authenticated operator, which may allow remote attackers to perform actions with the permissions of the user on the Sunny WebBox Firmware Version 1.6 and prior. This device uses IP addresses to maintain communication after a successful login, which would increase the ease of exploitation. | ||||
| CVE-2019-13524 | 1 Emerson | 18 Rx3i Cpe100, Rx3i Cpe100 Firmware, Rx3i Cpe115 and 15 more | 2024-11-21 | 7.5 High |
| GE PACSystems RX3i CPE100/115: All versions prior to R9.85,CPE302/305/310/330/400/410: All versions prior to R9.90,CRU/320 All versions(End of Life) may allow an attacker sending specially manipulated packets to cause the module state to change to halt-mode, resulting in a denial-of-service condition. An operator must reboot the CPU module after removing battery or energy pack to recover from halt-mode. | ||||
| CVE-2019-13522 | 1 Ezautomation | 1 Ez Plc Editor | 2024-11-21 | 7.8 High |
| An attacker could use a specially crafted project file to corrupt the memory and execute code under the privileges of the EZ PLC Editor Versions 1.8.41 and prior. | ||||